600/1000V Singlecore LSOH rubber cable with jacket
Cross-sectional Area
1.0mmsq -400 mmsq
Voltage rating
600/1000V
Conductor
Flexible Stranded Tinned Copper
Number of cores
1
Conductor class
IEC 60228 Class 5
Insulation
Cross linked EPR rubber type EI 110 or equivalent, in accordance with EN 50264-1
Jacket
Cross linked EVA rubber type EM104 or equivalent, in accordance with EN 50264-1
Fire standard
BS 6853 Categories la, lb and ll and NFF 16 101 FO
No of Cores/Pairs
Cross Sectional Area(mmsq)
Number and Nominal Diameter of Strands(mm)
Voltage Rating(V)
Nominal Overall Diameter
(mm)
Nominal Weight
(kg/km)
Singlecore
1.0
32/0.20
600/1000
5.9
54.0
Singlecore
1.5
30/0.75
600/1000
6.2
60.0
Singlecore
2.5
50/0.25
600/1000
6.6
74.0
Singlecore
4.0
56/0.30
600/1000
7.2
94.0
Singlecore
6.0
84/0.30
600/1000
7.7
124.0
Singlecore
10.0
80/0.40
600/1000
9.1
129.0
Singlecore
16.0
126/0.40
600/1000
10.2
248.0
Singlecore
25.0
196/0.40
600/1000
11.6
352.0
Singlecore
35.0
276/0.40
600/1000
13.1
454.0
Singlecore
50.0
396/0.40
600/1000
14.9
619.0
Singlecore
70.0
360/0.50
600/1000
17.0
838.0
Singlecore
95.0
475/0.50
600/1000
19.0
1077.0
Singlecore
120.0
608/0.50
600/1000
21.1
1352.0
Singlecore
150.0
756/0.50
600/1000
22.9
1648.0
Singlecore
185.0
925/0.50
600/1000
24.9
1989.0
Singlecore
240.0
1221/0.50
600/1000
28.0
2585.0
Singlecore
300.0
1525/0.50
600/1000
31.8
3229.0
Singlecore
400.0
2013/0.50
600/1000
35.5
4165.0